Chirp 3210 Echosounder

Specifications

Units:
Metres, Feet or Fathoms.

Main Ranges:

Feet or Fathoms
10
20
50
100
200
500
1000
2000
5000

Phased Ranges:
Multiple 50% overlapped phases of each range (20% overlap optional), manual or automatic selection.

Frequencies:
One or two low frequency channels: 3.5kHz to 24kHz, 24-bit A/D Optional high frequency channel: 24kHz to 210kHz, 16-bit A/D.

Power:
4 user-selectable power levels up to 1kW per channel

Depth Resolution:
1 cm (0-99.99),
1 dm (100-999.9),
1 m (>1000 )

1/100 ft (0-99.99),
1/10 (100-999.9) ft,
1ft (>1000)

1/100 fm (0-99.99),
1/10 fm (100-999.9 fm),
1 fm (>1,000 fm)

Sound Velocity:
1300 - 1700 m/s Resolution 1 m/s,
4265 - 5577 ft/s Resolution 1 ft/s,
710 - 929 fm/s Resolution 1 fm/s

Draft:
0 - 100 m Resolution: 1 cm
0 - 328.08 ft Resolution: 0.01 ft
0 - 54.68 fm Resolution: 0.01 fm

Pulse Length:
To 64ms, user-selectable.

Gain Controls:
AGC, TVG and manual receive gain for each frequency.

Interface:
USB 2.0 hi-speed (480Mbps)

Knudsen SounderSuite-USB Software:
Windows 2000, and Windows XP compatible.
Post-Processing Software.
Control: Easy to use graphical user interface(GUI).
Display: Scrolling echogram with depth overlay, plus digital depth.
Heave: Supports all popular heave sensors.
Position: Supports all popular GPS receivers.
Printers: Standard Windows printers plus all popular thermal printers.
Simultaneous operation with other Survey software such as HYPACK.

Output Data:
Full resolution envelope data in XTF (sidescan) and KEL format.
Industry standard SEG-Y in 16-bit fixed point or 32-bit floating point format in user-selected raw, filtered, or envelope detected form.
User-configurable ASCII digital depth strings

Additional Features:
Convenient USB interface to Windows PC and SounderSuite-USB.
Frequency Agility.
Dynamic Range: instantaneous 118dB, overall 160+ dB.
Pulselengths to 64ms.
Multiple pings in the water column.
Full-spectrum chirp and correlation processing on all channels.
Heave-corrected echograms.
Pinger Mode.
Network Operation: Supports multiple instances on networked PCs.
All Digital: No calibration or analog alignment required - ever!
All new design.
Latest DSP technology.

Options:
Transducers (many are available).
Transducer 'over the side' mounting brackets.
On-site training/installation.